Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Case Report
Case Report, GI/GU/Thoracic/Non Vascular Interventions
Case Report, Interventional Oncology
Case Report, Interventional Radiology
Case Report, Pediatric Interventional Radiology
Case Report, Vascular Interventions
Case Series
Case Series, Interventional Oncology
Case Series, Vascular Interventions
Editorial
GI/GU/Thoracic/Non-Vascular Interventions, Case Report
GI/GU/Thoracic/Non-vascular Interventions, Original Article
GI/GU/Thoracic/Non-Vascular Interventions, Original Research
GI/GU/Thoracic/Nonvascular Interventions, Case Report
Interventional Oncology, Case Report
Interventional Oncology, Original Research
Interventional Oncology, Patient Care, Practice Management and Education
Interventional Oncology, Technical Innovation
Interventions Oncology, Case Report
Interventions Oncology, Original Research
Letter to Editor
Letter to the Editor
Musculoskeletal Interventions, Case Report
Original Research
Original Research, GI/GU/Thoracic/Non-vascular Interventions
Original Research, GI/GU/Thoracic/Nonvascular Interventions
Original Research, Interventional Oncology
Original Research, Neurologic Interventions
Original Research, Vascular Interventions
PATIENT CARE, PRACTICE MANAGEMENT AND EDUCATION
Patient Care, Practice Management and Education, Original Research
Pediatric Interventional Radiology, Case Report
Pediatric Interventional Radiology, Original Article
Pediatric Interventional Radiology, Original Research
Research Article
Review Article
Review Article, Vascular Interventions
TECHNICAL INNOVATION
Technical Innovation, GI/GU/Thoracic/Nonvasculat Interventions
Technical Innovation, Interventional Oncology
Vascular Interventions, Case Report
Vascular Interventions, Original Research
Vascular Interventions, Technical Innovation
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Case Report
Case Report, GI/GU/Thoracic/Non Vascular Interventions
Case Report, Interventional Oncology
Case Report, Interventional Radiology
Case Report, Pediatric Interventional Radiology
Case Report, Vascular Interventions
Case Series
Case Series, Interventional Oncology
Case Series, Vascular Interventions
Editorial
GI/GU/Thoracic/Non-Vascular Interventions, Case Report
GI/GU/Thoracic/Non-vascular Interventions, Original Article
GI/GU/Thoracic/Non-Vascular Interventions, Original Research
GI/GU/Thoracic/Nonvascular Interventions, Case Report
Interventional Oncology, Case Report
Interventional Oncology, Original Research
Interventional Oncology, Patient Care, Practice Management and Education
Interventional Oncology, Technical Innovation
Interventions Oncology, Case Report
Interventions Oncology, Original Research
Letter to Editor
Letter to the Editor
Musculoskeletal Interventions, Case Report
Original Research
Original Research, GI/GU/Thoracic/Non-vascular Interventions
Original Research, GI/GU/Thoracic/Nonvascular Interventions
Original Research, Interventional Oncology
Original Research, Neurologic Interventions
Original Research, Vascular Interventions
PATIENT CARE, PRACTICE MANAGEMENT AND EDUCATION
Patient Care, Practice Management and Education, Original Research
Pediatric Interventional Radiology, Case Report
Pediatric Interventional Radiology, Original Article
Pediatric Interventional Radiology, Original Research
Research Article
Review Article
Review Article, Vascular Interventions
TECHNICAL INNOVATION
Technical Innovation, GI/GU/Thoracic/Nonvasculat Interventions
Technical Innovation, Interventional Oncology
Vascular Interventions, Case Report
Vascular Interventions, Original Research
Vascular Interventions, Technical Innovation
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Case Report
Case Report, GI/GU/Thoracic/Non Vascular Interventions
Case Report, Interventional Oncology
Case Report, Interventional Radiology
Case Report, Pediatric Interventional Radiology
Case Report, Vascular Interventions
Case Series
Case Series, Interventional Oncology
Case Series, Vascular Interventions
Editorial
GI/GU/Thoracic/Non-Vascular Interventions, Case Report
GI/GU/Thoracic/Non-vascular Interventions, Original Article
GI/GU/Thoracic/Non-Vascular Interventions, Original Research
GI/GU/Thoracic/Nonvascular Interventions, Case Report
Interventional Oncology, Case Report
Interventional Oncology, Original Research
Interventional Oncology, Patient Care, Practice Management and Education
Interventional Oncology, Technical Innovation
Interventions Oncology, Case Report
Interventions Oncology, Original Research
Letter to Editor
Letter to the Editor
Musculoskeletal Interventions, Case Report
Original Research
Original Research, GI/GU/Thoracic/Non-vascular Interventions
Original Research, GI/GU/Thoracic/Nonvascular Interventions
Original Research, Interventional Oncology
Original Research, Neurologic Interventions
Original Research, Vascular Interventions
PATIENT CARE, PRACTICE MANAGEMENT AND EDUCATION
Patient Care, Practice Management and Education, Original Research
Pediatric Interventional Radiology, Case Report
Pediatric Interventional Radiology, Original Article
Pediatric Interventional Radiology, Original Research
Research Article
Review Article
Review Article, Vascular Interventions
TECHNICAL INNOVATION
Technical Innovation, GI/GU/Thoracic/Nonvasculat Interventions
Technical Innovation, Interventional Oncology
Vascular Interventions, Case Report
Vascular Interventions, Original Research
Vascular Interventions, Technical Innovation
View/Download PDF

Translate this page into:

Vascular Interventions
Case Report
2023
:7;
5
doi:
10.25259/AJIR_26_2022

Arteriovenous shunt status post-coronary artery bypass graft surgery treated with microcoil placement: A case report

Department of Education, A.T. Still University-Kirksville College of Osteopathic Medicine, Kirksville, Missouri,
Department of Cardiology, McLaren Macomb, Mount Clemens, Roseville, Michigan, United States.
Department of Interventional Radiology, McLaren Macomb, Mount Clemens, Roseville, Michigan, United States.
Department of Cardiology, Cardiology Associates of Michigan, Roseville, Michigan, United States.
Author image

*Corresponding author: Victoria Reick-Mitrisin, A.T. Still University-Kirksville College of Osteopathic Medicine, Liberty Township, Ohio, United States. sa202038@atsu.edu

Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

How to cite this article: Reick-Mitrisin V, Mohan J, Stenz J, Zainea M. Arteriovenous shunt status post-coronary artery bypass graft surgery treated with microcoil placement: A case report. Am J Interv Radiol 2023;7:5.

Abstract

Accidental cardiac arteriovenous (AV) anastomoses is a rare but severe complication of coronary artery bypass grafting. This can result in high output heart failure if left untreated. Little research has been done on the mainstays of treatment for this condition. Our patient is an 82-year-old male with a history of known coronary artery disease, status post-coronary bypass grafting surgery, presented with increasing shortness of breath, which was initially determined clinically to be due to high output heart failure, which was later confirmed during cardiac catheterization procedure. Coronary cardiac catheterization was carried out 2 weeks prior at an outside hospital for which the graft, which is supposed to be anastomosed of the circumflex, inadvertently anastomosed to the coronary sinus. The patient returned to the cardiac catheter lab and repeat angiography was performed. The left to right shunt was subsequently embolized using microcoils. He tolerated the procedure well. No recurrent anginal and/or heart failure symptoms were present. Interventional cardiology began the procedure by gaining right common femoral access. Next the saphenous vein graft to the coronary sinus was engaged with a 6 French JRy (Medtronic Inc., Minneapolis, MN) guide catheter and a 0.014” coronary wire was placed into the graft. Then interventional radiology advanced a 2.4 French microcatheter (Terumo, Ann Arbor, MI USA) over the 0.014” wire (Abbott Vascular Devices, Plymouth MN) into the mid to distal aspect of the bypass graft. Four detachable 0.018” microcoils (Terumo, Ann Arbor, MI USA) were carefully placed within the bypass graft. Subsequent angiogram demonstrated complete occlusion of the bypass graft with resolution of the AV shunt. Due to the acuity of the patient’s symptoms and the long timeframe from originally attempting stenting, no additional attempts to stent the circumflex were performed. Follow-up angiogram through the base catheter demonstrates complete occlusion of the bypass graft with resolution of the AV shunt. No contrast was seen entering the coronary sinus. The patient tolerated the procedure well with no immediate complications. Estimated blood loss was <10 mL. The patient was admitted overnight for further evaluation. No shortness of breath noted. He was discharged in good condition the following day. Accidental cardiac AV anastomosis is a rare complication of coronary artery bypass grafting that could lead to high output heart failure. In such cases, catheter directed embolization with microcoils can be done to occlude the AV shunt created by the previously placed cardiac catheter with resolution of heart failure symptoms.

Keywords

Coronary artery bypass graft
Arteriovenous shunt
Coil embolization
Multidisciplinary
Coronary artery embolization

INTRODUCTION

Inadvertent cardiac arteriovenous (AV) anastomoses are a rare and potentially severe complication of coronary artery bypass grafting surgery. This can result in high output heart failure if left untreated. Little research has been done on the mainstays of treatment for this condition. This case report describes endovascular management of an inadvertent AV shunt through the coronary sinus. Successful occlusion of the coronary artery bypass graft was completed with coil embolization, leading to resolution of high output heart failure symptoms. This case demonstrates both the treatment of a rare condition and successful collaboration across multidisciplinary teams.

CASE REPORT

Our patient is an 82-year-old male with a history of known coronary artery disease, status post coronary bypass grafting surgery, presenting with increasing shortness of breath. He was found to have a left to right shunt causing high output heart failure by hemodynamic assessment [Figure 1]. Coronary angiography was performed 2 weeks prior at an outside hospital that demonstrated a saphenous vein graft, which was supposed to be anastomosed to the obtuse marginal branch of the circumflex, but instead was inadvertently anastomosed to the coronary sinus.

A 82-year-old male presenting with increasing shortness of breath and was subsequently found to have high output heart failure. Contrast-enhanced fluoroscopic imaging of the patients coronary vasculature demonstrated a saphenous vein graft, which is supposed to be anastomosed to the obtuse marginal branch of the circumflex, was inadvertently anastomosed to the coronary sinus. Catheter and successfully placed coils depicted above with black arrow.
Figure 1:
A 82-year-old male presenting with increasing shortness of breath and was subsequently found to have high output heart failure. Contrast-enhanced fluoroscopic imaging of the patients coronary vasculature demonstrated a saphenous vein graft, which is supposed to be anastomosed to the obtuse marginal branch of the circumflex, was inadvertently anastomosed to the coronary sinus. Catheter and successfully placed coils depicted above with black arrow.

A multidisciplinary approach was taken with discussions between interventional cardiology, cardiothoracic surgery, and interventional radiology on the best treatment approach for the patient. The decision was made to treat the patient endovascular with the use of microcoils. Interventional cardiology began the procedure by gaining right common femoral access. Next the saphenous vein graft to the coronary sinus [Figure 2] was engaged with a 6 French JRy (Medtronic Inc., Minneapolis, MN) guide catheter and a 0.014” coronary wire was placed into the graft. Then interventional radiology advanced a 2.4 French microcatheter (Terumo, Ann Arbor, MI USA) over the 0.014” wire (Abbott Vascular Devices, Plymouth MN) into the mid to distal aspect of the bypass graft. Four detachable 0.018” microcoils (Terumo, Ann Arbor, MI USA) were carefully placed within the bypass graft. Subsequent angiogram demonstrated complete occlusion of the bypass graft with resolution of the AV shunt. No contrast was seen entering the coronary sinus. Hemodynamic assessment confirmed resolution of the shunt. The patient tolerated the procedure well with no immediate complications. Estimated blood loss was <10 mL. The patient was admitted overnight for further evaluation. No shortness of breath noted. He was discharged in good condition the following day. Left ventricular systolic function improved to 50% status post procedure.

A 82-year-old male presenting with increasing shortness of breath and was subsequently found to have high output heart failure. Contrast-enhanced fluoroscopic imaging of the patients coronary vasculature demonstrated successful occlusion of the coronary arteriovenous shunt status post microcoil placement. Catheter and successfully placed coils depicted above with black arrow.
Figure 2:
A 82-year-old male presenting with increasing shortness of breath and was subsequently found to have high output heart failure. Contrast-enhanced fluoroscopic imaging of the patients coronary vasculature demonstrated successful occlusion of the coronary arteriovenous shunt status post microcoil placement. Catheter and successfully placed coils depicted above with black arrow.

DISCUSSION

The incidence of coronary AV fistulas is between 0.2% and 2%, with most cases being congenital. As the patient increases in age, they are more likely to have complications. Our case is unique in that the cause of the AV shunt is iatrogenic rather than congenital in origin, rarely previously reported in the literature.[3] Although rarely procedurally related, proper diagnosis and treatment of AV coronary shunts are critical, as the long-term complications can be significant and potentially irreversible. It is important to note that the successful treatment of this rare condition was achieved using a multidisciplinary approach. There is currently little literature present on the successful reversal of AV shunts due to iatrogenic injury, and even less about the use of multidisciplinary teams in the operating room. The most common complication being the “coronary steal” phenomenon, which occurs due to the shunting of blood from a high-pressure part of the circulatory system to the lower pressure vessels in the pulmonary vasculature.[3] Historically, coronary artery fistulas were evaluated with conventional invasive angiography but computed tomographic angiography is now the recommended option due to the short acquisition time and high spatial and temporal resolution.[4] A low clinical suspicion to perform this procedure is important due to the potential long-term sequelae if left untreated.

There are a variety of treatment options for coronary AV shunts outlined in the literature, including the transcatheter approach as described in our patient, surgical treatment, and pharmacotherapy to reduce heart failure symptoms.[3] While asymptomatic cases do not require immediate treatment, more severe cases could lead significant and irreversible consequences.[3] Catheter directed embolization is the gold standard due to its low complication rate and higher efficacy compared to surgical or medical management. However, vessel tortuosity and lumen size limit the ability to perform this in certain patients.[5] When reasonable an endovascular approach should be considered because the rate of recurrence with catheter embolization is 9–19% compared to surgical management with a 25% rate of recurrence.[6]

There has been an uptick in use of the endovascular catheter approach, due to the advancement in procedural equipment available. With little literature detailing a successful treatment strategy in iatrogenic cases, early documentation of a successful multidisciplinary approach is useful to consider for future cases. This is important to determine the best method of embolization (plug vs. coil) due to the complex cardiac vascular anatomy and potential risks for post-procedural complications. Controlled release coils have been shown to have significantly contributed to catheter-based method of embolization and control of perforations in the coronary arteries, with one study reporting successful occlusion in 97% of patients.[7] Covered stents have been shown to be efficacious in the treatment of cardiac shunts and in the reduction of reflow rate. In addition, these shunts may concomitantly exist with pseudoaneurysm. The presence of a pseudoaneurysm may further alter the treatment of the patient. It is important to take a multidisciplinary approach to patient management as these cases are rare and individual anatomy and shunt location can alter treatment strategies.[8] Further research should be directed towards finding ways to increase use of this treatment modality in a larger patient population due to the less invasive nature of the procedure and high success rate.[9]

CONCLUSION

Inadvertent cardiac AV anastomosis is a rare complication of coronary artery bypass grafting that can lead to high output heart failure. As shown in our case, an endovascular approach with microcoils is a viable treatment strategy to occlude an AV shunt due to iatrogenic injury from a previous intervention using catheter-directed embolization.[1,2]

Acknowledgments

Thank you, Dr. Mohan and Dr. Stenz, for your procedural efforts and work with advising and manuscript coaching. Thank you, Dr. Zainea, for your incredible work following and caring for this patient. All your efforts on this unique case led to exceptional patient outcomes.

Declaration of patient consent

Patient’s consent not required as patients identity is not disclosed or compromised.

Conflicts of interest

There are no conflict of interest.

Financial support and sponsorship

Nil.

References

  1. , , , , , . Management of coronary artery fistulae. Patient selection and results of transcatheter closure. J Am Coll Cardiol. 2002;39:1026-32.
    [CrossRef] [PubMed] [Google Scholar]
  2. , , , , . Transcatheter closure of coronary artery fistulas. J Am Coll Cardiol. 1992;20:205-9.
    [CrossRef] [PubMed] [Google Scholar]
  3. , , , , . Coronary arteriovenous fistulae: A review. Int J Angiol. 2014;23:1-10.
    [CrossRef] [PubMed] [Google Scholar]
  4. , , . Coronary artery fistulas: Pathophysiology, imaging findings, and management-erratum. Radiographics. 2018;38:2214.
    [CrossRef] [Google Scholar]
  5. , , , . Percutaneous coronary artery fistula closure in adults: Technical and procedural aspects. Catheter Cardiovasc Interv. 2007;69:872-80.
    [CrossRef] [PubMed] [Google Scholar]
  6. , , , , , , et al. Diagnostic and therapeutic approach of congenital solitary coronary artery fistulas in adults: Dutch case series and review of literature. Neth Heart J. 2011;19:183-91.
    [CrossRef] [PubMed] [Google Scholar]
  7. , . Catheter closure of coronary artery fistulas. J Interv Cardiol. 2001;14:299-307.
    [CrossRef] [PubMed] [Google Scholar]
  8. , , . Aortocoronary saphenous vein graft aneurysm with fistula to the right atrium: Percutaneous management of surgical complication In: Del Med J. Vol 87. . p. :370-5.
    [Google Scholar]
  9. , , , , . Transcatheter embolization in the treatment of coronary artery fistulas. J Am Coll Cardiol. 1991;18:187-92.
    [CrossRef] [PubMed] [Google Scholar]

Fulltext Views
38,675

PDF downloads
3,027
View/Download PDF
Download Citations
BibTeX
RIS
Show Sections